Future Roof Shingle — CAD Details & Installation Drawings

Downloadable CAD detail drawings for Future Roof Shingle metal roofing — eaves, ridges, valleys, and flashing details for design and installation.

Page last updated:

About Future Roof

This document is part of the roofbook.com library — the official, primary-source document library for Future Roof metal roofing. It is published by Future Roof. Learn more at https://www.futureroof.com.

Future Roof Shingle — CAD Details & Installation Drawings — frequently asked questions

What does the Future Roof Shingle CAD detail set contain?

It is a set of CAD detail drawings (13 sheets) for Future Roof Shingle metal roofing. It includes the shingle profile (9.44" x 18.12" overall, 8.625" x 17.375" exposed) with its interlocking sidelap, baselap and headlap, plus starter/rake, valley, gable/rake, hip and ridge, oval/gambrel/ridge, collar, endwall/sidewall, pipe (jack) flashing and side- and endwall flashing details. Each sheet carries its own file name, section and date.

Who should use these shingle CAD details and why?

They are intended for designers and installers who need exact geometry for the shingle and its terminations — dimensions, bend angles and the weather-sealed "S" lock interlock. A designer can reference them in project drawings while an installer follows them for starter, valley, hip and flashing conditions so the interlocking, weatherproof connection is achieved.

What slope and starter condition do the shingle details specify?

The starter detail specifies a minimum pitch of 3 in 12 with the interlocking weather-proof "S" lock design, an exposed depth to weather of 8.625" per course, over underlayment on solid sheathing with a starter strip at the eave. The valley detail shows each shingle bent to fit the interlocking side lap, and the hip detail describes forming a hip starter by cutting and bending the shingle's interlocking nose-end tabs.

What flashing and penetration details are included for the shingle system?

The set covers collar (10'), endwall and sidewall flashing (10'), a shingle pipe (jack) flashing showing the nose end cut to fit around the pipe with water diverters, and side- and endwall flashing detail where the cut shingle's top edge is inserted into the endwall flashing and held by a nailing clip. These give designers the standard penetration and wall-transition conditions.

In what format are the shingle CAD details provided?

Each drawing is a Future Roof Systems detail sheet (Delta, B.C. Canada) with an individual file reference such as AS_SHINGLE_A, AS_START_D, AS_VAL_D and AS_PIPFL_D plus a section and date. They form part of the Architectural Package (which includes a CAD-CAM CD) available from Future Roof customer service for use in design software.

FULL INTERLOCKING SIDELAP

Page 1

FULL INTERLOCKING SIDELAP FULL INTERLOCKING SIDELAP NAILING TAB CLOSEUP OF FULL INTERLOCKING SIDELAP FULL INTERLOCKING BASELAP FULL INTERLOCKING HEADLAP BUILT IN NAIL TAB 1/8" STAMPED STEP FOR EXTRA STRENGTH AND MOISTURE DIVERSION DIMENSIONS: 8.625" X 17.375" EXPOSED 0.375" BUTT EDGE SHINGLE PROFILE 9.44" X 18.12" OVERALL SHINGLE DELTA, B.C. CANADA V4G 1M8 9969 RIVER WAY FUTURE ROOF SYSTEMS FILE: AS_SHINGLE_A R PAGE SECTION: 1 DATE: JUNE 2003

1.25"

Page 2

1.25" 0.5" 0.5" 0.375" 1.125" 1.0" 0.625" 1.0" 40° 90° 30° 30° STARTER & RAKE (10 FT.) DELTA, B.C. CANADA V4G 1M8 9969 RIVER WAY FUTURE ROOF SYSTEMS FILE: AS_START_A R PAGE SECTION: 1 DATE: JUNE 2003

UNDERLAYMENT

Page 3

UNDERLAYMENT MININUM PITCH: 3 IN 12 INTERLOCKING WEATHER-PROOF "S" LOCK DESIGN DEPTH OF EACH COURSE TO WEATHER 8.625" SHEATHING STARTER STRIP RAFTER STARTER DETAIL DELTA, B.C. CANADA V4G 1M8 9969 RIVER WAY FUTURE ROOF SYSTEMS FILE: AS_START_D R PAGE SECTION: 1 DATE: JUNE 2003

20°

Page 4

20° 1.0" 4.75" 4.0" VALLEY (10 FT.) DELTA, B.C. CANADA V4G 1M8 9969 RIVER WAY FUTURE ROOF SYSTEMS FILE: AS_VAL_A R PAGE SECTION: 1 DATE: JUNE 2003

SHINGLE VALLEY

Page 5

SHINGLE VALLEY EACH SHINGLE IS BENT TO FIT INTERLOCKING SIDE LAP FASCIA STARTER STRIP VALLEY DETAIL DELTA, B.C. CANADA V4G 1M8 9969 RIVER WAY FUTURE ROOF SYSTEMS FILE: AS_VAL_D R PAGE SECTION: 1 DATE: JUNE 2003

GABLE & STARTER

Page 6

GABLE & STARTER FASCIA SHINGLE GABLE END OR RAKE DETAIL DELTA, B.C. CANADA V4G 1M8 9969 RIVER WAY FUTURE ROOF SYSTEMS FILE: AS_GARA_D R PAGE SECTION: 1 DATE: JUNE 2003

REAR INTERLOCKING SIDE LAP

Page 7

REAR INTERLOCKING SIDE LAP .75" INTERLOCKING NOSE END TAB FASTENING APRON 7.5" 5.0" 1.0" 1.0" 1.75" 11.0" 4.0" HIGH PROFILE HIP & RIDGE SHINGLE TRIM DELTA, B.C. CANADA V4G 1M8 9969 RIVER WAY FUTURE ROOF SYSTEMS FILE: AS_HIPRISHINTRIM_A R PAGE SECTION: 1 DATE: JUNE 2003

Hip Starter is made by cutting the top of the

Page 8

Hip Starter is made by cutting the top of the shingle hip and ridge back approximately 1.5". With the bending tool form the interlocking nose end tabs at 90° approximately 1.0" above bend again at 90° to complete the hip starter. The interlocking nose end tabs fit under the starter strip nose end . Pull back and fasten. FASCIA SHINGLE MITERED AND OVERLAPPED AT THE HIP, MINIMUM 2" 1.0" 0.5" HIP DETAIL DELTA, B.C. CANADA V4G 1M8 9969 RIVER WAY FUTURE ROOF SYSTEMS FILE: AS_HIP_D R PAGE SECTION: 1 DATE: JUNE 2003

RAFTER

Page 9

RAFTER WEATHER SEALED LOCKING JOINT UNDERLAYMENT SHEATHING RAFTER RAFTER OVAL DETAIL GAMBREL DETAIL RIDGE DETAIL 8.625" TO WEATHER 8.625" TO WEATHER 8.625" TO WEATHER OVAL, GAMBREL & RIDGE DELTA, B.C. CANADA V4G 1M8 9969 RIVER WAY FUTURE ROOF SYSTEMS FILE: AS_OVGAMRI_D R PAGE SECTION: 1 DATE: JUNE 2003

1.0"

Page 10

1.0" 7.0" 0.5" COLLAR (10 FT.) DELTA, B.C. CANADA V4G 1M8 9969 RIVER WAY FUTURE ROOF SYSTEMS FILE: AS_COL_A R PAGE SECTION: 1 DATE: JUNE 2003

4.0"

Page 11

4.0" 1.0" 0.75" 2.625" 0.875" 1.75" ENDWALL & SIDEWALL (10 FT.) DELTA, B.C. CANADA V4G 1M8 9969 RIVER WAY FUTURE ROOF SYSTEMS FILE: AS_ENDWLSIDWL_A R PAGE SECTION: 1 DATE: JUNE 2003

NOSE END OF SHINGLE CUT TO

Page 12

NOSE END OF SHINGLE CUT TO FIT AROUND BACK OF PIPE JACK CONE PIPE JACK APRON PIPE JACK CONE .5" BENDBACK WATER DIVERTERS EXPOSED FRONT OF PIPE JACK FASTENERS FELT OVERLAY FELT OVERLAY SHINGLE PIPE FLASHING DELTA, B.C. CANADA V4G 1M8 9969 RIVER WAY FUTURE ROOF SYSTEMS FILE: AS_PIPFL_D R PAGE SECTION: 1 DATE: JUNE 2003

THE TOP EDGE OF THE CUT SHINGLE

Page 13

THE TOP EDGE OF THE CUT SHINGLE IS INSERTED INTO THE ENDWALL FLASHING. NAILING CLIP ATTACHED TO THE LOCKING CLIP OF THE CUT SHINGLE NAIL TAB OF BOTTOM SHINGLE SIDE & ENDWALL FLASHING END & SIDE WALL DETAIL DELTA, B.C. CANADA V4G 1M8 9969 RIVER WAY FUTURE ROOF SYSTEMS FILE: AS_ENDSIDWAL_D R PAGE SECTION: 1 DATE: JUNE 2003

CAD Details
The Peak of Protection

All Pages